A heated 48V deep-cycle LiFePO4 battery for off-grid, solar, RV, van and boat house power, with Bluetooth monitoring and Victron GX communication.
The Epoch 48V 125Ah Essential Series (model 48125A-COMM) stores 6.40kWh (6,400Wh nominal, 51.2V) in one battery. It delivers and accepts up to 150A continuously, supplies 300A for up to 10 seconds for start-up surges, uses incoming charger current to heat its cells so it can charge in freezing weather, balances its 16 cells with a 2A active balancer, and reports to the Epoch Li-Ion app over Bluetooth and to Victron Cerbo GX and Ekrano GX devices over CAN. Each battery weighs 110 lb in a 25.2 × 9.65 × 8.66 in IP54 case, and up to 15 can be connected in parallel.
Key Features
-
48V 125Ah Essential Series LiFePO4 (6.40kWh): Heated 48V deep-cycle power for off-grid and solar storage, RV, van and boat house power, golf carts and backup systems, storing 6,400Wh (nominal, 51.2V) in one battery built for a dry, protected location.
-
Victron CAN Comms: Reports to a Victron Cerbo GX or Ekrano GX over CAN-bus. With DVCC on, the GX applies the battery's charge voltage limit and discharge current limit to the Victron chargers and inverter chargers, and the battery's integrated shunt supplies state of charge, so a separate battery monitor is not required. Linked batteries select a master automatically, with no DIP switches or addresses, and the GX shows the whole bank as one battery.
-
Both Communication Cables Included: In the box with the battery are a battery-to-battery communication cable for linking RS485-OUT to the next battery's RS485-IN, and a master battery-to-Victron CAN cable that runs from the CAN port of Battery 1 (the first battery in the chain) to the GX's BMS-Can or VE.Can 2 port. Make only one CAN connection per bank.
-
High-Output Power Delivery: 150A maximum continuous discharge and 300A peak for up to 10 seconds for start-up surges from inverters, motors and compressors. At 51.2V, 150A is about 7,680W of DC power before inverter losses; size the system by the inverter's DC input current, not its AC output, and keep any load lasting longer than 10 seconds at or below 150A.
-
150A Charging, 48V LiFePO4 Profile: Accepts up to 150A continuous charge from all sources combined, with up to 62.5A (0.5C) recommended. Program every source for 48V LiFePO4: 56.8V–57.6V bulk/absorption, float 54.0V–55.2V or off (preferred), equalization and temperature compensation disabled, and never program a charge voltage above 57.6V (58.0V is the maximum charge voltage).
-
Heated for Cold-Weather Charging: Rated to charge from -30°C to 55°C (-22°F to 131°F) with internal heating. When the cells reach 0°C (32°F), the BMS stops charging and sends the incoming charge current from a connected charger (at least 0.5A) to the internal heating pads, never stored battery energy; charging resumes automatically when the cells reach 5°C (41°F). Discharge is rated from -20°C to 55°C (-4°F to 131°F).
-
Bluetooth Monitoring: The Epoch Li-Ion app for iOS and Android shows state of charge, voltage, current, temperature and protection status, and switches charging and discharging on or off independently. While the POWER button has discharge switched off, the app cannot switch discharge on or off, and neither the app nor the button is a means of isolation; for storage or service, open a DC disconnect or remove the battery cables.
-
2A Active Cell Balancing: Moves charge between the 16 cells whenever their voltages differ by more than 0.015V, keeping them matched without user intervention.
-
Smart BMS Protection: Built-in protection against overcharge, over-discharge, over-current, short circuit and high or low temperature, with an integrated shunt (0.2A accuracy on discharge) for state of charge. It does not replace correctly sized fuses or breakers.
-
Parallel Expansion, No Series: Up to 15 matched 48125A-COMM batteries in parallel (1,875Ah / 96.00kWh at 51.2V). Series wiring is not approved for this model.
-
IP54 Rated ABS Case: Dust-protected and splash-resistant, 25.2 × 9.65 × 8.66 in (640 × 245 × 220 mm), 110 lb (50 kg). IP54 is not waterproof: install it upright in a dry, protected location, and do not submerge it, pressure wash it or mount it where standing water can collect.
-
7,000+ Cycle Life & 11-Year Limited Warranty: Rated for 7,000+ cycles with no watering or acid service, and covered by an 11-year limited warranty (3 years of free replacement, then 40% off MSRP on a replacement battery through Year 11) against qualifying defects in materials and workmanship. Register within 90 days or keep your proof of purchase.
Key Benefits
-
Splash & dust resistant (IP54): Protected against limited dust ingress and water splashes. Not waterproof or submersible.
-
Cycle life (7,000+): Over 19 years at one full cycle a day. Rated at the depth of discharge, charge rate and temperature stated on the datasheet, to its end-of-life capacity.
-
Bluetooth app (iOS + Android): Charge, voltage and temperature on your phone in the Epoch Li-Ion app.
-
Protection (Advanced BMS): Guards against overcharge, over-discharge, overcurrent and short circuit.
-
Cold weather (Self-heating): Warms its cells before charging, so it can charge in freezing weather.
-
Thermal stability (LiFePO4): Lithium iron phosphate has a far lower thermal-runaway risk than other lithium chemistries. The BMS adds over-temperature and low-temperature charge protection.
Built for 48V off-grid and Victron systems
-
Both cables included: Battery-to-battery & Victron CAN
-
Victron communications: Cerbo GX & Ekrano GX over CAN
-
11-year limited warranty: 3 yrs free replacement
-
Bluetooth monitoring: Epoch Li-Ion app
-
Internal heating: Cold-weather charging
-
2A active balancing: 16 cells kept matched
Run 48V Inverter Systems on 150A Continuous Power
One 51.2V battery for 48V inverter chargers, solar banks and golf-cart controllers.
This 48V 125Ah LiFePO4 battery delivers and accepts up to 150A continuously. At 51.2V, 150A is about 7,680W of DC power before inverter losses. Size the system by the inverter's DC input current, not its AC output: it must stay within 150A per battery, and the AC output is lower because of conversion losses.
The 300A peak rating covers start-up surges from inverters, motors and compressors for up to 10 seconds; any load that lasts longer must stay at or below 150A. Set the inverter's low-voltage shutdown above the bottom of the operating range (41.6V) so the inverter stops before the BMS disconnects the battery, and use chargers, inverters, fuses and switches rated for a 48V (51.2V nominal) LiFePO4 system, up to 58.0V while charging.
Charger-Powered Internal Heating
Internal heating pads let the battery charge in freezing weather, for a charge temperature range of -30°C to 55°C (-22°F to 131°F) with internal heating. When the cells reach 0°C (32°F), the BMS stops charging and uses the incoming charge current to power the heater; charging resumes automatically when the cells reach 5°C (41°F). The heater runs only while a charger is connected and supplying at least 0.5A, and it never uses the battery's stored energy. Discharging works down to -20°C (-4°F) without heating.
Victron CAN, Battery Linking & Bluetooth
Connected to a Victron Cerbo GX or Ekrano GX over CAN-bus with DVCC on, the battery reports its state of charge, voltages, temperatures and alarms, and sends the charge voltage and discharge current limits that the Victron chargers and inverter chargers follow. Use the BMS-Can port on a Cerbo GX MK1, or VE.Can 2 set to 500 kbit/s on a Cerbo GX MK2 or Ekrano GX. Batteries in a bank link through their RS485 ports and select a master automatically, with no DIP switches or addresses, and the GX shows the linked bank as one battery. Over Bluetooth, the Epoch Li-Ion app for iOS and Android shows state of charge, voltage, current, temperature and protection status.
Both Communication Cables Included
Both data cables come in the box. The battery-to-battery communication cable links RS485-OUT on one battery to RS485-IN on the next, so a bank shares data down the chain. The master battery-to-Victron CAN cable connects the CAN port of Battery 1 to the GX's BMS-Can or VE.Can 2 port; make only one CAN connection per bank. Fit the caps on all unused ports. If more length is needed, a standard Cat 7 Ethernet patch cable can be used between the battery's CAN port and the GX port.
Expandable, Protected, and Built for the Long Haul
Expand to 15 batteries in parallel: up to 1,875Ah and 96.00kWh at 51.2V.
The 110 lb (50 kg) battery measures 25.2 × 9.65 × 8.66 in (640 × 245 × 220 mm) in an ABS plastic case with threaded red (+) and black (-) terminals and end handles for lifting. Its IP54 enclosure is dust-protected and splash-resistant but not waterproof, so install it upright in a dry, protected location. Up to 15 matched 48125A-COMM batteries can be connected in parallel; series connection is not approved for this model.
2A active balancing engages when cell voltages differ by more than 0.015V, keeping the 16 cells matched without user intervention, and the built-in smart BMS protects against overcharge, over-discharge, over-current, short circuit and high or low temperature. The battery is rated for 7,000+ cycles and carries an 11-year limited warranty (3 years of free replacement, then 40% off MSRP on a replacement battery through Year 11) against qualifying defects in materials and workmanship. Register within 90 days or keep your proof of purchase.
Battery features
Heated 48V LiFePO4 power with Victron CAN, Bluetooth monitoring, active balancing and both communication cables included.
-
Both communication cables included: A battery-to-battery cable for the RS485 link and a master battery-to-Victron CAN cable for the GX come in the box.
-
125Ah / 6.40kWh capacity: Stores 6,400Wh (nominal, 51.2V) of 48V deep-cycle energy in one battery.
-
150A continuous discharge: About 7,680W of DC power at 51.2V before inverter losses, for properly sized 48V inverter systems.
-
300A peak discharge: Covers start-up surges from inverters, motors and compressors for up to 10 seconds only.
-
150A continuous charge: Up to 150A from all sources combined, up to 62.5A (0.5C) recommended; program 56.8V–57.6V bulk/absorption and never program a charge voltage above 57.6V (58.0V is the maximum charge voltage).
-
Internal heating: Charge current powers the heater at 0°C (32°F) and charging resumes at 5°C (41°F); the heater runs only while a charger supplying at least 0.5A is connected.
-
Victron CAN communications: Reports to a Cerbo GX or Ekrano GX over CAN-bus with DVCC; the integrated shunt supplies state of charge, so a separate battery monitor is not required.
-
Bluetooth app monitoring: State of charge, voltage, current, temperature and protection status in the Epoch Li-Ion app for iOS and Android.
-
2A active balancing: Engages when cell voltages differ by more than 0.015V to keep the 16 cells matched.
-
IP54 enclosure: Dust-protected and splash-resistant. Not waterproof: do not submerge, pressure wash, or install where standing water can collect.
-
Parallel expansion: Up to 15 matched batteries in parallel (1,875Ah / 96.00kWh). Series wiring is not approved for this model.
-
7,000+ cycles, 11-year limited warranty: No watering or acid service. 11-year limited warranty against defects in materials and workmanship: 3 years of free replacement, then 40% off MSRP on a replacement battery through Year 11. Register within 90 days or keep your proof of purchase.
IP54 splash-resistant protection
Dust-protected and splash-resistant, for dry, protected installations. Not waterproof.
Under IEC 60529, IP54 means dust-protected (5) and protected against splashing water from any direction (4). The enclosure is not waterproof: it is not designed for submersion, pressure washing, bilge flooding or continuous water exposure. Install the battery in a dry, protected location, do not mount it where standing water can collect around the case or terminals, and keep the caps fitted on unused data ports to keep out dust and water.
Why upgrade to Epoch LiFePO4?
Flat voltage. Long cycle life. No watering or acid service.
Compared with lead-acid batteries, LiFePO4 (lithium iron phosphate) chemistry gives a flat voltage curve, long cycle life and maintenance-free service. The 48125A-COMM needs no watering or acid service, and its built-in battery management system monitors the cells and disconnects them when operating limits are exceeded. Routine inspections of the case, terminals, cables and charger settings still apply.
Fitment and installation note
Verify your inverter, charger, wiring, and installation location before use.
Confirm that the compartment fits the 25.2 in L × 9.65 in W × 8.66 in H case, with clearance above the terminals for cable bend radius, terminal covers and inspection. The battery weighs about 110 lb (50 kg), so use two people or a lifting aid and lift by the end handles. Mount it upright and secure it with a tray, strap, bracket or battery box so it cannot slide or tip; never rely on the terminals or cables to restrain it. Tighten the terminal bolts securely without over-tightening the threaded inserts, place a DC-rated main fuse or breaker as close as practical to the battery positive terminal, and confirm polarity with a multimeter before the final connection. Do not hot-connect batteries, and pre-charge large inverters where required.
Applications and use cases
- Off-grid solar systems
- Off-grid cabins
- Off-grid home energy storage
- Solar battery banks and inverter systems
- RV house power (48V systems)
- Van house power (48V systems)
- Boat house power (dry protected installation)
- Golf carts (controller within 150A continuous)
- Utility vehicles (controller within 150A continuous)
- Backup power
- Large battery banks (up to 15 in parallel)
- Victron Cerbo GX and Ekrano GX systems
At a glance
- 125Ah capacity
- 6.40kWh stored energy
- 150A continuous output
- 300A 10 sec peak
- 110 lb battery weight
- IP54 splash resistant
Compatible charging equipment
- Program every charging source for 48V LiFePO4 operation, with equalization and temperature compensation disabled. Combined charge current from all sources must stay at or below 150A per battery.
- 48V LiFePO4 chargers, converters and inverter chargers that can be set to the recommended values, including the Epoch 48V 15A Lithium Battery Charger
- Solar charge controllers (MPPT or PWM) with a programmable or LiFePO4 profile
- DC-to-DC chargers for alternator charging
- Victron systems with a Cerbo GX or Ekrano GX, where CAN comms let the battery set charge limits through DVCC
What Can It Run?
Epoch plans runtime on 80% of the 6,400Wh nominal energy, about 5,120Wh per battery. Runtime in hours is roughly 5,120Wh divided by the load in watts.
| Load |
Estimated Run Time |
| 500W |
≈ 10.2 hours |
| 1,000W |
≈ 5.1 hours |
| 2,560W (50A) |
≈ 2.0 hours |
| 3,000W |
≈ 1.7 hours |
| 5,000W |
≈ 1.0 hour |
These are DC estimates at 25°C on a new, fully charged battery; inverter losses, cabling, temperature, battery age and duty cycle change real results. For a parallel bank, multiply by the number of batteries.
Suitable For:
- Off-grid cabins, homes and solar energy storage with 48V inverter chargers and MPPT solar charge controllers.
- RV and van house power built around a 48V inverter charger, installed in a dry, protected location.
- Boat house power in dry, protected compartments, installed to applicable marine electrical standards and the boat manufacturer's requirements.
- Victron systems with a Cerbo GX or Ekrano GX, using CAN communication and DVCC.
- Golf carts and utility vehicles whose motor controller stays within 150A continuous, with peaks of no more than 300A for up to 10 seconds.
- Backup power for 48V systems.
- 48V DC loads, and 12V loads through a 48V-to-12V DC-DC converter.
- Large banks of up to 15 batteries in parallel (96.00kWh).
Certifications & Standards
-
IP54: Dust-protected, and protected against splashing water from any direction. Under IEC 60529 the first digit rates solids and the second rates water.
-
CE: The manufacturer's declaration that the product meets the European Union's health, safety and environmental requirements, which is required to sell it in the European Economic Area.
-
RoHS: Complies with the EU Restriction of Hazardous Substances directive, which limits lead, mercury, cadmium and other toxic materials in electronics.
-
UN 38.3: The United Nations test series every lithium battery must pass before it can be shipped by air, sea or road.
Please Note: Deep-cycle battery; not a cranking battery.
Please Note: Series connection is not approved; up to 15 matched batteries in parallel only.
Please Note: Size loads, conductors and fuses to the 150A continuous rating; the 300A rating applies for up to 10 seconds only. Size inverters by DC input current, not AC output.
Please Note: Set the inverter low-voltage shutdown above 41.6V so it stops before the BMS disconnects.
Please Note: Never program a charge voltage above 57.6V; combined charge current from all sources must stay at or below 150A per battery.
Please Note: The internal heater runs only while a charger supplying at least 0.5A is connected; it never uses stored energy.
Please Note: Neither the POWER button nor the app is a means of isolation; open a DC disconnect or remove the battery cables for storage or service.
Please Note: The BMS does not replace correctly sized fuses or breakers; place a DC-rated main fuse or breaker as close as practical to the positive terminal.
Please Note: IP54 is not waterproof: install upright in a dry, protected location; do not submerge, pressure wash or install where standing water can collect.
Please Note: Make only one CAN connection per bank; fit caps on all unused data ports.
Please Note: Use matched batteries of the same age, condition and state of charge; fully charge each before connecting it into a bank.
Please Note: Long-term storage: charge to about 30–50%, disconnect loads, and check at least every 3 months.
Please Note: Weighs about 110 lb (50 kg): use two people or a lifting aid and lift by the end handles.
-
Specifications
General
Brand: Epoch Batteries
Model / SKU: 48125A-COMM
Series: Essential Series
Battery type: Heated 48V deep-cycle LiFePO4 battery with Bluetooth, RS485 / CAN and Victron communication
Primary use: 48V energy storage for off-grid and solar systems, RV, van and boat house power, golf carts and backup power, installed in a dry, protected location
Chemistry: LiFePO4 / Lithium iron phosphate
Cell type: Grade-A prismatic LiFePO4
Cell configuration: 16S1P
Bluetooth: Yes — Epoch Li-Ion app, iOS and Android
Victron communications: Yes — Victron CAN-bus (GX / DVCC)
Battery linking: RS485-IN / RS485-OUT ports; the batteries select a master automatically, with no DIP switches or addresses
Internal heating: Yes — internal heating pads; runs only while a charger supplying at least 0.5A is connected
Active balancing: Yes — 2A active balancing, engages above 0.015V cell difference
Current measurement: Integrated shunt, 0.2A accuracy on discharge
Cycle life: 7,000+ cycles
Warranty: 11-year limited warranty: free replacement in Years 1–3, then 40% off MSRP on a replacement battery in Years 4–11. Register within 90 days or keep your proof of purchase.
Voltage and capacity
Nominal voltage: 51.2V
Nominal capacity: 125Ah
Energy stored: 6.40kWh (6,400Wh)
Operating voltage range: 41.6V – 58.0V
Maximum charge voltage: 58.0V
Current ratings
Max continuous discharge: 150A
Max continuous charge current: 150A, all charging sources combined
Recommended charge current: Up to 62.5A (0.5C, 50% of capacity); up to 50% of bank capacity for parallel banks
Max discharge peak current: 300A for up to 10 seconds
Continuous DC power: About 7,680W (150A at 51.2V), before inverter losses
Estimated runtime (80% planning energy, 5,120Wh): 500W ≈ 10.2 h · 1,000W ≈ 5.1 h · 2,560W (50A) ≈ 2.0 h · 3,000W ≈ 1.7 h · 5,000W ≈ 1.0 h; DC loads at 25°C on a new, fully charged battery; real results vary
Configuration
Series connections: Not approved for this model
Parallel connections: Up to 15 batteries
Maximum configuration: 15P: 1,875Ah / 96.00kWh at 51.2V, matched batteries and rated equipment
System design note: Use matched 48125A-COMM batteries of the same age, condition and state of charge; fully charge each one before connecting it, fuse each battery, and use equal cable lengths and gauges to the busbars
Communication wiring: RS485-OUT to the next battery's RS485-IN; CAN port of Battery 1 to the GX; one CAN connection per bank
Temperature
Charge temperature range: -30°C to 55°C / -22°F to 131°F, with internal heating
Discharge temperature range: -20°C to 55°C / -4°F to 131°F
Recommended storage temperature: 0°C to 35°C / 32°F to 95°F up to 1 year; -20°C to 45°C / -4°F to 113°F up to 1 month
Low-temperature charge protection: Heater on at 0°C (32°F); charging resumes at 5°C (41°F); the heater runs on charger current (at least 0.5A), never stored energy
Long-term storage: Charge to about 30–50% state of charge, disconnect loads, and check state of charge at least every 3 months, recharging if needed; batteries left uncharged for more than three months are excluded from warranty coverage
Dimensions and weight
Length: 25.2 in / 640 mm
Width: 9.65 in / 245 mm
Height: 8.66 in / 220 mm
Overall dimensions: 25.2 in L × 9.65 in W × 8.66 in H (640 × 245 × 220 mm)
Weight: 110 lb / 50 kg
Mechanical
Case material: ABS plastic
Enclosure protection: IP54 (IEC 60529) — dust-protected and splash-resistant; not waterproof, not submersible
Terminal type: Threaded inserts, red (+) / black (-)
Terminal hardware: Use bolts that match the terminal thread and tighten securely; do not over-tighten
Data ports and controls: RS485-IN, RS485-OUT and CAN ports with caps; POWER button switches discharge output off or on (not a means of isolation)
Mounting orientation: Upright
In the box: One 48125A-COMM battery, a battery-to-battery communication cable, and a master battery-to-Victron GX CAN communication cable
Recommended charging settings
Bulk / absorption voltage: 56.8V – 57.6V; do not program a charge voltage above this range
Float voltage: 54.0V – 55.2V; off is preferred where the charger allows it
Equalization: Disabled
Temperature compensation: 0 mV/°C (disabled)
Charge temperature range: -30°C to 55°C / -22°F to 131°F (with internal heating)
Victron GX systems: CAN with DVCC on: the battery sends its charge voltage limit and discharge current limit, and the chargers' own absorption and float settings are overridden
BMS protection
Overcharge protection: Yes
Over-discharge protection: Yes
Over-current protection: Yes
Short-circuit protection: Yes
High and low temperature disconnects: Yes
Compliance
Compliance marks: CE, RoHS, WEEE
Transport: UN 38.3, Class 9
Quick specifications
Cell Configuration: 16S1P
Chemistry: LiFePO4
Ah Capacity: 125Ah
Max Continuous Discharge Amps: 150A
Max Charge Current Amps: 150A (up to 62.5A recommended)
Max Discharge Peak Current Amps: 300A (up to 10 Seconds)
Series | Parallel: Parallel only: Max (15) in Parallel (1,875Ah); no series
Voltage: 51.2V
Max Charge Voltage: 58.0V
Operating Voltage Range: 41.6 - 58.0V
Charge Temp Range: -30°C (-22°F) / 55°C (131°F) (with internal heating)
Discharge Temp Range: -20°C (-4°F) / 55°C (131°F)
Storage Temp: 0°C (32°F) / 35°C (95°F) (up to 1 year); -20°C (-4°F) / 45°C (113°F) (up to 1 month)
Weight: 110 lbs
Length: 25.2 in
Width: 9.65 in
Height: 8.66 in
Compliance marks: CE, RoHS, WEEE
Transport: UN 38.3, Class 9
In the Box
- One 48125A-COMM battery
- Battery-to-battery communication cable (RS485-OUT to the next battery's RS485-IN)
- Master battery-to-Victron GX CAN communication cable
-
Recommended Charging Settings
- Maximum Continuous Charge Current: 150A per battery, all charging sources combined
- Recommended Charge Current: Up to 62.5A (0.5C) per battery; up to 50% of bank capacity for parallel banks (125A for 2, 250A for 4, 500A for 8, 937.5A for 15), within charger, wiring and system limits
- Bulk/Absorption: 56.8V-57.6V
- Float Voltage: Disabled (preferred) or 54.0V-55.2V
- Temperature Compensation: 0 mV/°C (disabled)
- Equalization: Disabled; do not use lead-acid equalization, desulfation or repair modes
- Maximum Charge Voltage: 58.0V; do not program a charge voltage above 57.6V
- Charge Temperature Range: -30°C to 55°C (-22°F to 131°F) with internal heating; when the cells reach 0°C (32°F) the BMS stops charging and uses the incoming charge current to power the internal heater, never stored energy, and charging resumes automatically when the cells reach 5°C (41°F); the heater runs only while a charger is connected and supplying at least 0.5A
- Cold Weather: leave the charger connected and switched on so the heater can warm the cells, and make sure the charging source can supply at least 0.5A in the cold; solar charging stops at night, so the heater runs only while the panels are producing; discharging works down to -20°C (-4°F) without heating
- Charging Sources: 48V LiFePO4 battery chargers (such as the Epoch 48V 15A Lithium Battery Charger), MPPT or PWM solar charge controllers with a programmable or LiFePO4 profile, DC-to-DC chargers for alternator charging, and converters or inverter chargers that can be set to these values
- Victron chargers without a GX: program each Victron solar charge controller and inverter charger with a user-defined 48V LiFePO4 profile using the settings above (user manual section 10)
- Note: If a charger cannot be fully programmed, confirm its bulk/absorption voltage is within range and that equalization and temperature compensation are disabled. If a charger asks for absorption-time or end-current settings, avoid long lead-acid absorption periods. A charger below 62.5A is suitable; it simply takes longer.
Victron GX setup (Cerbo GX or Ekrano GX)
- Connect the CAN port of Battery 1 to the GX with the included master battery-to-Victron CAN cable. Make only one CAN connection per bank.
- Cerbo GX MK1: use the BMS-Can port; the GX detects the battery automatically.
- Cerbo GX MK2 or Ekrano GX: use the VE.Can 2 port and set its CAN-bus speed to 500 kbit/s.
- Turn DVCC on, with Shared voltage sense (SVS) and Shared temperature sense (STS) on.
- Select the CAN-LV battery under Battery monitor.
- With DVCC on, the GX applies the battery's charge voltage and discharge current limits, and the chargers' own absorption and float settings are overridden. The integrated shunt supplies state of charge, so a separate battery monitor is not required.
- If more length is needed, a standard Cat 7 Ethernet patch cable can be used between the battery's CAN port and the GX port.
Linking several batteries into one bank
- Make and check all power connections first, with chargers and loads switched off.
- Run a battery-to-battery communication cable from RS485-OUT on Battery 1 to RS485-IN on Battery 2, then from RS485-OUT on Battery 2 to RS485-IN on Battery 3, and so on down the chain.
- Connect only Battery 1's CAN port to the GX with the master battery-to-Victron CAN cable.
- The batteries select a master automatically, with no DIP switches or addresses to set, and the GX shows the linked bank as one battery.
- Fit the caps on all unused ports.
-
48125A-COMM Specification Sheet (Rev V01, October 2026)
48125A-COMM User Manual (Rev V01, October 2026)
48125A-COMM Data Sheet (Rev V01, October 2026)
Safety Data Sheet (LiFePO4)
-
What comes in the box with the Epoch 48V 125Ah battery?
The box includes the 48125A-COMM battery and both communication cables: a battery-to-battery communication cable for linking RS485-OUT to the next battery's RS485-IN, and a master battery-to-Victron CAN cable for connecting the CAN port of Battery 1 (the first battery in the chain) to a Cerbo GX or Ekrano GX. Plan the power side separately: size the battery cables, lugs, fuses or breakers and busbars for your system's current, cable length and voltage drop, and charge with a 48V LiFePO4 charger.
Does the 48V 125Ah Essential battery work with Victron Cerbo GX and Ekrano GX?
Yes. It communicates with Victron GX devices over CAN-bus. On a Cerbo GX MK1, connect the battery's CAN port to the BMS-Can port and the GX detects it automatically. On a Cerbo GX MK2 or Ekrano GX, use the VE.Can 2 port, set its CAN-bus speed to 500 kbit/s, turn DVCC on with shared voltage sense and shared temperature sense on, and select the CAN-LV battery as the battery monitor. With DVCC on, the GX applies the battery's charge voltage and discharge current limits to the Victron chargers and inverter chargers, and the battery's integrated shunt supplies state of charge, so a separate battery monitor is not required.
How do I link several batteries into one bank?
Make and check all power connections first, with chargers and loads switched off. Then run a battery-to-battery communication cable from RS485-OUT on Battery 1 to RS485-IN on Battery 2, continue from RS485-OUT on Battery 2 to RS485-IN on Battery 3 and so on down the chain, and connect only Battery 1's CAN port to the GX with the master battery-to-Victron CAN cable. The batteries select a master automatically, with no DIP switches or addresses to set, and the GX shows the linked bank as one battery. Fit the caps on all unused ports.
How many batteries can I connect, and can I wire them in series?
Up to 15 matched 48125A-COMM batteries can be connected in parallel, for 1,875Ah and 96.00kWh at 51.2V nominal. Series connection is not approved for this model. Use batteries of the same age, condition and state of charge, fully charge each one before connecting it into the bank, fuse each battery, and use equal cable lengths and gauges to the busbars.
What size inverter can it run?
At 51.2V, the 150A continuous rating is about 7,680W of DC power before inverter losses, so size the system by the inverter's DC input current, not its AC output. The 300A rating covers start-up surges from inverters, motors and compressors for up to 10 seconds only; any load that lasts longer must stay at or below 150A per battery. Set the inverter's low-voltage shutdown above 41.6V so the inverter stops before the BMS disconnects the battery.
How long will it run my loads?
Epoch plans runtime on 80% of the 6,400Wh nominal energy, about 5,120Wh per battery. Runtime in hours is roughly 5,120Wh divided by the load in watts: about 10.2 hours at 500W, 5.1 hours at 1,000W, 1.7 hours at 3,000W and 1.0 hour at 5,000W. These are DC estimates at 25°C on a new, fully charged battery; inverter losses, cabling, temperature, battery age and duty cycle change real results. For a parallel bank, multiply by the number of batteries.
Can it charge in freezing weather?
Yes, with a charger connected. When the cells reach 0°C (32°F), the BMS stops charging and uses the incoming charge current to power the internal heater; charging resumes automatically when the cells reach 5°C (41°F). The heater runs only while a charger is connected and supplying at least 0.5A, and it never uses the battery's stored energy. Solar charging stops at night, so on solar alone the heater runs only while the panels are producing. Charging is rated from -30°C to 55°C (-22°F to 131°F) with internal heating, and discharging from -20°C to 55°C (-4°F to 131°F).
Is this battery waterproof?
No. This model is IP54 rated, meaning it is dust-protected and splash-resistant. It should not be submerged, pressure washed, or installed where standing water can collect around the case or terminals. Install it upright in a dry, ventilated, protected location, and keep the caps fitted on unused data ports.
What charger settings should I use?
Program every charging source for 48V LiFePO4: bulk/absorption 56.8V to 57.6V, float 54.0V to 55.2V or off, equalization disabled and temperature compensation at 0 mV/°C, and never program a charge voltage above 57.6V. The recommended charge current is up to 62.5A, and combined current from all sources must not exceed 150A per battery. Suitable sources include 48V LiFePO4 chargers such as the Epoch 48V 15A Lithium Battery Charger, solar charge controllers with a programmable or LiFePO4 profile, DC-to-DC chargers, and converters or inverter chargers that can be set to these values.
Can I use it in a golf cart?
Yes, where the motor controller's battery current stays within 150A continuous for one battery, and acceleration and hill-climbing peaks stay within 300A for no more than 10 seconds. It is a deep-cycle battery, not a cranking battery. Secure it upright against vibration and protect it from water spray, because IP54 is splash-resistant, not waterproof. Charge it with a 48V LiFePO4 charger, and confirm that the 25.2 × 9.65 × 8.66 in, 110 lb case fits the cart.
-
Epoch Batteries Limited Warranty
Warranty Period
11-year limited manufacturer warranty
Years 1–3: free replacement against qualifying defects in materials and workmanship
Years 4–11: 40% off MSRP on a replacement battery
Register within 90 days or keep your proof of purchase
Batteries left uncharged for more than three months are excluded from warranty coverage
Epoch Batteries-branded products are covered against qualifying defects in materials and workmanship for the applicable warranty period, subject to Epoch's model-specific remedy schedule and the terms of its warranty policy. Epoch-branded chargers carry a 2-year limited warranty and accessories (such as fuel gauges and voltage reducers) a 1-year limited warranty, from the original purchase date.
Registration
Register your battery with Epoch within 90 days of purchase for full warranty coverage. If it is not registered within that time, the warranty period begins from the battery's original manufacturing date. Proof of ownership is required for any claim, and coverage is non-transferable and applies only to the original purchaser.
Remedy
After inspection and testing, Epoch will provide the applicable remedy for a qualifying manufacturing defect: an approved repair, a replacement, or a comparable-product offer according to the model's schedule. Typical repair turnaround is 3–10 business days once the product is received.
Exclusions
Coverage may be denied when a failure is caused by misuse, improper handling, installation or storage, or use outside the product's specifications. Examples include an unsecured battery; loose, corroded or improperly connected terminals; series or parallel connections beyond the manufacturer's recommendations; reverse polarity or short circuits; impact, fire or water submersion; storage above 140°F or below -40°F; prolonged storage fully discharged or batteries left uncharged for more than three months; poor crimps, undersized cables or damaged wiring; opened, modified or tampered products; and use in applications the battery was not designed for, including repeated engine starting on non-cranking models.
Obtaining Warranty Service
Start a claim through the Epoch Batteries Warranty Portal with your model and serial number, proof of purchase, a description of the issue and supporting photos or videos. If approved, Epoch provides an RMA number and packing instructions. Do not ship a product without a valid RMA. The customer arranges and pays for shipment to Epoch, packaged in compliance with lithium battery shipping rules. Epoch Batteries can be reached at 1-888-501-1846 or support@epochbatteries.com.
Visit Epoch's Warranty Page to review the full warranty terms.
-
Shipping is typically through freight carriers and the actual shipping time is contingent on your location and the specific warehouse dispatching your order. Please allow for a 1-3 business day processing period before shipment, and an estimated delivery time of up to 7 business days. Your confirmation email will include delivery details and we will send you a tracking number as soon as one is available. If you ordered several separate items, you may receive multiple tracking numbers. Once the item has been shipped, the freight service will contact you to coordinate the date and time of delivery. If you require any special accommodations during delivery please let us know as soon as possible and let the delivery company know when arranging the appointment.
Typically, orders will be dropped off either curbside or outside your front door or garage. It is your responsibility to bring the order inside or to its final destination and to remove any existing items.
Depending on the item, parts may be shipped in multiple boxes, and assembly may be required. When your order is delivered, please check that you have all pieces of the item and that nothing is damaged. If your order is damaged during transit and external damage is visible, note the damage immediately, write it on the delivery documents, take photos and/or videos, and refuse shipment. If there is no visible external damage, accept the package but note “subject to concealed damage” on the delivery documents. Any damage upon delivery needs to be reported within 24 hours of delivery or you may not be eligible for a refund. For additional information on submitting claims, as well as incorrect item exchanges, and replacements, please see our Refund Policy.
For more information about shipping, please visit our complete Shipping Policy.
-
Why Shop With Eco Emperor?
At Eco Emperor, our mission is to empower you to lead a sustainable and fun lifestyle with ease and confidence. Whether you're upgrading your outdoor experience or enhancing your eco-conscious journey, here’s why choosing us is a decision you can feel great about:
Expert and Customized Care
Our knowledgeable and friendly team is here to support you every step of the way. We pride ourselves on providing personalized service and swift responses to ensure a smooth and satisfying experience. Our dedicated team is available via phone, email, and live chat to provide you with prompt and helpful support.
Authorized Retailer of High-Quality, Trusted Products from Leading Brands
We partner with the best brands in the industry to bring you reliable, high-quality products. As authorized retailers, we guarantee authenticity and offer full manufacturer warranties on every item. You can trust that our products are built to last and perform efficiently.
Free & Fast Shipping
We know you’re eager to begin your new products or start your next outdoor adventure. That’s why we prioritize quick, reliable, and free shipping to get your orders to you on time and in perfect condition.
Competitive Pricing
We believe that sustainable living should be accessible to everyone. We offer competitive pricing on all our products, so you can enjoy high-quality eco-friendly solutions and outdoor products without breaking the bank.
Choose Eco Emperor for all your outdoor and eco-friendly product needs, and become part of a movement that’s embracing a more sustainable and adventurous lifestyle.
Thank you for supporting a greener, cleaner future, while enhancing your outdoor experiences and powering your adventures.💚