A premium 5.89kWh lithium battery for advanced marine, RV, Victron, and 24V off-grid solar systems.
The Epoch 24V 230Ah V2-T Elite is a high-capacity 24V 230Ah LiFePO4 battery engineered around a user-serviceable 300A Class-T fuse, native Victron CANBus communication, internal heating, Bluetooth monitoring, and an IP67 enclosure. Its 5.89kWh energy platform gives system builders a compact, managed battery for demanding marine house banks, RV power systems, and professional off-grid energy storage.
Key Features
-
24V 230Ah V2-T Elite Series LiFePO4 (5.89kWh): 25.6V, 230Ah and 5,888Wh of nominal stored energy in one managed, sealed case for premium marine house banks, RVs and 24V off-grid solar systems; plan runtime on about 4,710Wh. A deep-cycle battery, not for engine starting.
-
User-Serviceable 300A Class T Fuse: An Eaton Bussmann JJN-300 (20kA interrupting rating at 160V DC) under a protected service cover on the lid reduces fault energy at the battery outlet. It does not replace system protection: install a DC-rated main fuse or breaker close to the battery positive, plus a disconnect and branch protection.
-
Native Victron Integration: CAN communication at 500 kbit/s to compatible GX devices (Cerbo GX, Ekrano GX); with DVCC on, the BMS sets the charge voltage and current limits of Victron chargers. Daisy-chain wiring only; the communication harness is included; set the DIP switches and GX settings per the manual.
-
115A Continuous Charge and Discharge: 115A at 25°C (about 2,944W DC before inverter losses), 250A for 5 seconds discharge and 180A for 5 seconds charge. If an inverter's continuous DC input can exceed 115A, add batteries in parallel.
-
IP67 Enclosure: Dust-tight and protected against temporary immersion to 1 meter for 30 minutes with all seals and glands installed. Not rated for water jets, pressure washing or continuous submersion; install it where it stays dry in normal use.
-
BMS-Controlled 153.6W Heater: The cells are not charged below 0°C (32°F); while charging, the heater switches on at 5°C (41°F) and off at 10°C (50°F), using incoming charge energy to warm the cells. Charging runs from 0°C to 50°C (32°F to 122°F); discharge from -20°C to 50°C (-4°F to 122°F).
-
Bluetooth Monitoring & External Controls: Bluetooth 4.0 through the included remote digital battery gauge to the free Epoch Cloud app (iOS and Android): state of charge, cell voltage, temperature, charge and discharge cycles and system health alerts. An external, mountable power button is included.
-
Scalable Banks: Up to 16 batteries in parallel (3,680Ah, 94.21kWh) or 2 in series (51.2V nominal, 58.0V at full charge); mixed series-parallel is not supported. Use matched C24230A-A batteries of the same age, capacity and state of charge.
-
Advanced BMS & Certified Components: Over/under-voltage, over-current, short-circuit and temperature protection, with UL 1642, UL 9540A and IEC 62619:2022 cells and a UL 60691 fuse component.
-
Dimensions & Mounting: 20.86 × 8.65 × 12.06 in (529.8 × 219.8 × 306.3 mm, height with terminal posts), 98.9 lb. Install upright on a flat, rigid surface; threaded inserts accept the optional Elite Series 8D mounting hardware. Replacing a Group 8D lead-acid battery? Confirm tray fit, hold-down and lid clearance first.
-
3,500+ Cycles & 11-Year Limited Warranty: 3,500+ cycles to 70% end-of-life capacity (25°C). Maintenance-free (no watering or equalizing), with regular inspections. 11-year limited manufacturer warranty; register within 90 days of purchase.
Key Benefits
-
Run Large Inverters: About 2,944W DC continuous, before inverter losses
-
Cold-Weather Charging: Heater warms cells below 5°C (41°F) while charging
-
Monitor via Bluetooth: Live data in the Epoch Cloud app
-
Victron Compatible: Seamless system integration
-
11-Year Warranty: Limited manufacturer warranty
-
3,500+ Cycles: To 70% end-of-life capacity at 25°C
Battery Intelligence
Bluetooth App Monitoring
Your whole system, in your pocket
Connect over Bluetooth 4.0 through the included battery gauge to see state of charge, cell voltage, temperature, charge and discharge cycles and system health alerts in the Epoch Cloud app.
Victron Integration
- State of charge
- Cell voltage
- Temperature
- Charge / discharge cycles
- System health alerts
Built to talk to your Victron system
Native CAN communication at 500 kbit/s with compatible Victron GX devices: the battery reports its status and charge limits, and with DVCC on it sets the charge voltage and current limits of Victron chargers. The communication harness is included; set the DIP switches and GX settings per the manual.
- GX Device Support
- Remote Monitoring
- DVCC Charge Control
- Seamless Integration
- Victron Ready
Built for demanding 24V energy systems
-
11-year warranty: Limited manufacturer coverage
-
Victron ready: CAN and DVCC integration
-
Internal heating: Cold-weather charging support
-
Bluetooth monitoring: Epoch Cloud app and included gauge
-
Certified cells: UL1642, UL9540A and IEC 62619:2022
-
Serviceable fuse: Protected top access
A 5.89kWh Energy Vault for Marine and Off-Grid Systems
Premium 24V storage with source protection, managed communications, and scalable architecture.
The V2-T platform is intended for deep-cycle house-power and energy-storage service rather than engine starting. One battery provides 230Ah at 25.6V nominal and supports large 24V loads without the complexity of wiring several smaller batteries in parallel.
The integrated fuse, CAN communication, remote gauge, external power control, heating, and Bluetooth monitoring reduce installation clutter—but installers must still provide the main disconnect, properly selected downstream overcurrent protection, branch fusing, busbars, conductors, securement, precharge where required, and a complete commissioning plan.
Safety: The V2-T Class T Fuse
High-interrupt source protection, managed BMS safeguards, and a sealed serviceable enclosure.
User-Serviceable 300A Class-T Fuse
The Eaton Bussmann JJN-300 has a 20kA interrupting rating at 160V DC and sits under a protected service cover on the lid. It reduces fault energy at the battery outlet, but it does not replace the main disconnect or downstream cable and branch protection: install a DC-rated fuse or breaker in the positive conductor, as close to the battery as practical.
Advanced BMS and Published Safety Listings
The embedded BMS supervises cell voltage, current, temperature, protection events, and balancing. Epoch publishes UL1642, UL9540A, and IEC 62619:2022 cell references, plus CE, RoHS, and fuse-related listing information.
IP67 Dust-Tight, Immersion-Rated Enclosure
The enclosure is dust-tight and rated for temporary immersion up to 1 meter for up to 30 minutes when every seal and gland is correctly installed. Treat IP67 as an ingress-protection test rating—not permission for permanent submersion, standing-water installation, water jets or pressure washing. Install the battery where it stays dry in normal use.
Premium Smart Features and Seamless Integration
Managed Victron charging, cold-weather operation, and real-time battery visibility.
Native Victron Integration via CANBus
The BMS communicates at 500kbit/s through the specified battery harness. A correctly configured Cerbo GX or Ekrano GX can use Epoch as the controlling BMS and battery monitor with DVCC enabled, allowing the battery to publish managed operating data and charging limits to the Victron system.
Cold-Weather Ready with Internal Heating
The 153.6W heater is controlled by the BMS. The cells are not charged below 0°C (32°F); while charging, the heater switches on at 5°C (41°F) and off at 10°C (50°F), using incoming charge energy to warm the cells before normal charging proceeds.
Bluetooth App and Physical Monitoring
Monitor state of charge, cell voltage, temperature, charge and discharge cycles and system health alerts in the Epoch Cloud app (iOS and Android), over Bluetooth 4.0 through the included battery gauge. The included remote digital gauge and external power button provide local access without opening the battery compartment.
Unrelenting Power and Massive Scalability
High-capacity standalone power with supported series or parallel expansion.
A single battery supports 115A continuous discharge (about 2,944W DC before inverter losses) and 250A for 5 seconds. Size inverters by their DC input current: a 2,000W load through a 90%-efficient inverter draws about 87A. If an inverter's continuous DC input can exceed 115A, add batteries in parallel. Uses include marine hotel loads, 24V trolling-motor and electric auxiliary systems where requirements match, and off-grid loads.
Scale to sixteen batteries in parallel for 3,680Ah and about 94.21kWh at 25.6V nominal, or use up to two matched batteries in series for a 51.2V nominal (48V-class) string, 58.0V at full charge. Mixed series-parallel banks are not supported.
Deep-cycle and installation boundary
This battery is for house-power and energy-storage service, not engine cranking. The Class-T fuse is a source-protection feature, not a complete electrical system. Qualified installers must design the disconnect, downstream protection, branch circuits, conductors, mounting, charging, monitoring, and documentation.
V2-T Elite features
Professional-grade source protection, communications, monitoring, and environmental capability.
-
300A Eaton Class-T fuse: User-serviceable JJN-300 source fuse with a published 20kA interrupt rating at 160VDC.
-
115A continuous discharge: Approximately 2.94kW of nominal DC output from one 25.6V battery before conversion losses.
-
115A continuous charging: 115A continuous (180A for 5 seconds) from lithium-compatible CC/CV equipment programmed to 28.4V absorption and 27.0V float.
-
Victron CAN communication: Managed battery data and DVCC-based charge control through a correctly configured GX system.
-
IP67 enclosure: Dust-tight and temporary-immersion rated when all seals and glands are properly installed.
-
153.6W internal heater: BMS-controlled 153.6W heater: on at 5°C and off at 10°C while charging; the cells are not charged below 0°C.
-
Bluetooth app monitoring: Track state of charge, cell voltage, temperature, cycles, and system alerts in the Epoch Cloud app.
-
External controls included: Mountable power button and remote digital battery gauge simplify access and status checks.
-
Advanced BMS protection: Monitors cell voltage, current, temperature, overcharge, over-discharge, and short-circuit conditions.
-
Passive convection cooling: No liquid cooling loop or serviceable cooling fan required.
-
Series or parallel support: Up to two in series or sixteen in parallel; mixed series-parallel is not supported.
-
Certified components: Published UL1642/UL9540A/IEC 62619:2022 cell, CE, RoHS, and fuse-related listings.
Recommended system components
Complete the installation with approved mounting, communications, charging, distribution, and service components.
-
Elite Series 8D mounting hardware: Official fitment support for C24230A-A securement in mobile and stationary installations.
-
Victron Cerbo GX or Ekrano GX: System control, DVCC, alarms, local display, and VRM remote monitoring.
-
Included: Epoch/Victron communication harness: Use the specified grey RJ45 BMS lead and battery daisy-chain harness rather than assuming a generic pinout.
-
Properly sized DC distribution: Busbars, disconnect, conductors, lugs, source protection, branch fuses, and precharge appropriate to the system.
-
24V lithium-compatible charge sources: Inverter/charger, MPPT solar controllers, AC charger, and DC-DC equipment programmed to Epoch settings.
-
Replacement Eaton JJN-300 fuse: Keep only the exact approved Class-T fuse and service procedure available for qualified maintenance.
Marine and ABYC installation note
A built-in Class-T fuse supports system safety—but compliance applies to the complete installation.
Installers searching for an ABYC-compliant marine battery system should evaluate the full design rather than the battery alone. Disconnect accessibility, source and branch protection, unfused conductor length, cable ampacity, securement, ignition-protection requirements, grounding, labeling, compartment conditions, and commissioning must all be addressed under the applicable standards and vessel design.
Installation and commissioning note
Secure the battery first, then engineer conductors, protection, precharge, charging, communications, and documentation.
Install on a flat rigid surface with service access to terminals, the fuse area, switch, and communication ports. Use approved restraints, short protected source conductors, appropriate busbars and lugs, controlled precharge for large capacitive loads, and equal-length conductors in parallel banks. Commission Victron communications, DIP settings, current limits, charging voltages, alarms, and module counts before placing loads into service.
Applications and use cases
- RV house power (24V systems)
- Camper vans and van life
- Travel trailers and fifth wheels
- Motorhomes and Class A or Class C coaches
- Overlanding and expedition vehicles
- Premium marine house banks
- Marine house power
- 24V trolling motors and electric auxiliary systems (where requirements match)
- Marine electronics and navigation
- Off-grid solar systems
- Solar battery banks and inverter systems
- Home energy storage and backup power
- Cabins and remote power systems
- 24V commercial mobile power
- Victron systems with a Cerbo GX or Ekrano GX
At a glance
- 230Ah capacity
- 5.89kWh stored energy
- 115A continuous output
- 300A class-t fuse
- IP67 ingress rating
- 16× parallel limit
What Can It Run?
Planning estimates for a single 5.89kWh battery, using 80% of nominal energy (about 4,710 Wh).
| Load |
Estimated Run Time |
| 2,944W DC Load |
≈ 1.6 Hours (4,710 Wh ÷ 2,944 W) |
| 1,000W DC Load |
≈ 4.7 Hours (4,710 Wh ÷ 1,000 W) |
| 500W DC Load |
≈ 9.4 Hours (4,710 Wh ÷ 500 W) |
| 100W DC Load |
≈ 47 Hours (4,710 Wh ÷ 100 W) |
Estimates are for a constant DC load at the battery terminals and use 80% of nominal energy, a planning figure that leaves reserve for battery life and cold conditions. Inverter losses, cable losses and temperature reduce runtime.
Suitable For:
- 24V off-grid solar systems for cabins, remote sites, backup power, and stationary energy storage.
- Victron-based systems using compatible Cerbo GX or Ekrano GX devices and managed BMS communication.
- Marine house banks for electronics, refrigeration, pumps, navigation, lighting, and other hotel loads.
- Large RV, expedition vehicle, and commercial mobile power systems using 24V inverter/chargers.
- 24V trolling-motor or electric auxiliary systems where current, voltage, charging, and manufacturer requirements match.
- Replacing a Group 8D lead-acid battery, after confirming tray fit, hold-down and lid clearance against 20.86 × 8.65 × 12.06 in.
- Parallel banks up to sixteen batteries for larger 24V energy-storage systems.
- Series strings of up to two batteries (51.2V nominal, 48V class), installed to the C24230A-A user manual.
Compare
| Model |
Capacity |
Energy |
Weight |
Bluetooth |
Heating |
Victron Ready |
| 12V 460Ah Elite |
460Ah |
5.89 kWh |
97 lbs |
Yes |
Yes |
Yes |
| 24V 230Ah Elite |
230Ah |
5.89 kWh |
98.9 lbs |
Yes |
Yes |
Yes |
| 48V 100Ah Elite |
100Ah |
5.12 kWh |
97 lbs |
Yes |
Yes |
Yes |
Certifications & Standards
-
IP67: Dust-tight, and protected against temporary immersion in up to 1 m of water for 30 minutes. Under IEC 60529 the first digit rates solids and the second rates water.
-
UL 1642: The UL standard for lithium cells. Each cell design is tested for fire and explosion risk under abuse before it is built into a pack.
-
UL 9540A: A UL test method that measures how a cell behaves if it goes into thermal runaway, and whether fire can spread to its neighbours. The data is used to design safer energy storage systems.
-
IEC 62619: The international safety standard for rechargeable lithium cells and batteries in industrial use, including stationary energy storage.
-
UL 60691: The UL standard for thermal-links: one-shot fuses that open when temperature climbs past a safe limit under a fault, cutting the circuit before anything overheats.
-
CE: The manufacturer's declaration that the product meets the European Union's health, safety and environmental requirements, which is required to sell it in the European Economic Area.
-
RoHS: Complies with the EU Restriction of Hazardous Substances directive, which limits lead, mercury, cadmium and other toxic materials in electronics.
Please Note: Deep-cycle house-power and energy-storage battery; not for engine starting.
Please Note: The internal Class T fuse does not replace the main disconnect, a DC-rated main fuse or breaker near the battery positive, or branch protection.
Please Note: Mixed series-parallel banks are not supported; use identical C24230A-A batteries of the same age, capacity and state of charge.
Please Note: IP67 is not permission for permanent submersion, standing water, water jets or pressure washing; install where it stays dry in normal use.
Please Note: Replacing a Group 8D battery: confirm tray fit, hold-down and lid clearance against 20.86 x 8.65 x 12.06 in.
Please Note: No single component makes an installation ABYC compliant; compliance depends on the complete system.
Please Note: Replace the fuse only with the exact approved model after fault diagnosis and isolation; qualified service is strongly recommended.
Also available as: 24V 230Ah V2 Elite Series | 24V 230Ah Essential Series
-
Specifications
Identification
Brand: Epoch Batteries
Product: 24V 230Ah V2-T Elite Series LiFePO4 Battery
Model / SKU: C24230A-A
Series: Epoch V2-T Elite Series
Battery duty: Deep-cycle house power and energy storage; not an engine-starting battery
Chemistry: LiFePO4 / lithium iron phosphate
Cell configuration: 8S1P
Published warranty: 11-year limited manufacturer warranty; register within 90 days of purchase
Voltage and Capacity
Nominal voltage: 25.6V
Rated capacity: 230Ah
Standard stored energy: 5.888kWh / approximately 5.89kWh
Maximum voltage (planning): 29.0V; never charge above 29.0V
Minimum voltage (planning): 20.8V
Operating state of charge: 0–100%
Internal resistance: ≤16mΩ
Self-discharge rate: ≤3% per month
Current Ratings
Continuous discharge current: ≤115A
Continuous charge current: ≤115A
Peak discharge: 250A for 5 seconds
Maximum charge, short duration: 180A for 5 seconds; 115A continuous for all charge sources combined
Nominal continuous DC output: Approximately 2,944W at 25.6V before inverter losses
Standard charge (rating method): CC ≤0.5C, CV 3.60V per cell (28.8V), end at 0.02C. Use the recommended charger settings below (28.4V absorption, 27.0V float).
Integrated Class-T Fuse
Fuse type: User-serviceable Eaton Class-T source fuse
Fuse model: Eaton JJN-300
Amperage rating: 300A
Interrupt rating: 20kAIC at 160VDC
Voltage rating: 300VAC / 160VDC
Short-circuit recovery: Replace approved fuse after fault diagnosis and controlled isolation
System-design limitation: Internal source fuse does not replace the main disconnect, downstream conductor protection, or branch protection
Series, Parallel and Communications
Supported standalone use: Yes
Series connections: Up to 2 identical C24230A-A batteries
Parallel connections: Up to 16 identical C24230A-A batteries
Mixed series-parallel: Not supported
Maximum parallel energy: About 94.21kWh nominal (3,680Ah) with 16 batteries
Battery communication: Bluetooth 4.0 and CAN-bus 500kbit/s
Victron integration: Compatible GX device using the specified BMS communication harness and DVCC configuration
Network layout: Daisy-chain; no branches or tee connections
Recommended Charging Settings
Bulk / absorption voltage: 28.4V (every charge source, Victron equipment included)
Absorption time: 15 minutes per battery in the bank
Float voltage: 27.0V
Equalization: Off / disabled
Temperature compensation: Disabled
Victron setup: Configure BMS-Can or VE.Can as instructed, enable DVCC, select Epoch as controlling BMS and battery monitor
Backup source programming: Program MultiPlus, Quattro, MPPT, and other charge sources to the same safe values in case CAN communication is lost
Temperature and Heating
Charge temperature: 0°C to 50°C / 32°F to 122°F, with heating support
Discharge temperature: -20°C to 50°C / -4°F to 122°F
Storage, one month or less: -20°C to 45°C / -4°F to 113°F
Storage, one year or less: 0°C to 35°C / 32°F to 95°F
Heater power: 153.6W
Heater voltage: 29.2VDC
Charge low-temperature protection: 0°C, with heating
Heater activation during charging: 5°C
Heater deactivation during charging: 10°C
Discharge low-temperature protection: -20°C
Mechanical
Dimensions: 20.86 × 8.65 × 12.06 in / 529.8 × 219.8 × 306.3mm
Weight: 98.9 lb / 45.86kg
Case material: PC + ABS, UL94 V-0
Terminals: M8 bolts
Terminal torque: 12N·m / 8.85lb-ft
Cooling: Passive convection
Ingress protection: IP67; dust-tight and temporary immersion ≤1m for ≤30 minutes with all seals/glands installed
Rated pressure: 86–106kPa
BMS Protection Values
Charge overcurrent protection: 180A ±2A with 5-second delay
Discharge overcurrent protection: 250A ±2A with 5-second delay
Charge high-temperature protection / release: 55°C / 53°C
Charge low-temperature protection / release: 0°C / 5°C with heating
Discharge high-temperature protection / release: 55°C / 53°C
Discharge low-temperature protection / release: -20°C / -17°C
Balancing and monitoring: Embedded BMS supervises cell voltage, current, temperature, protection, and balancing behavior
Lifecycle and Published Listings
Cycle life: 3,500+ cycles to 70% end-of-life capacity (25°C)
End-of-life test capacity: 70%
Published cell listings / standards: UL1642, UL9540A, IEC 62619:2022
Other published compliance: CE and RoHS; UN 3480, Class 9 (transport)
Published fuse-related listing: UL60691 fuse component listed on product page
Quick specifications
Energy Capacity: 5.89 kWh
Continuous Output: 115A @ 25°C
Peak Output: 250A (5 Seconds)
Max Charge Rate: 115A @ 25°C (180A for 5 Seconds)
Cell Configuration: 8S1P
Chemistry: LiFePO4
Voltage: 25.6V
Max Charge Voltage: 29.0V
Operating Voltage Range: 20.8 - 29.0V
Ah Capacity: 230Ah
Max Continuous Discharge Amps: 115A @ 25°C
Max Charge Current Amps: 115A @ 25°C (180A for 5 Seconds)
Max Discharge Peak Current Amps: 250A (5 Seconds)
Series | Parallel: Max (2) in Series OR Max (16) in Parallel
Charge Temp Range: 0°C (32°F) / 50°C (122°F) (with heating support)
Discharge Temp Range: -20°C (-4°F) / 50°C (122°F)
Storage Temp: 0°C (32°F) / 35°C (95°F) (up to 1 year); -20°C (-4°F) / 45°C (113°F) (up to 1 month)
Safety: 300A Class T Fuse, BMS (Battery Management System) Over Voltage, Under Voltage, Over-Current, Short Circuit, Over Temperature, Under Temperature
Length: 20.86 in
Width: 8.65 in
Height: 12.06 in
Weight: 98.9 lbs
Additional information
Certification: UL 1642, UL 9540A, IEC 62619:2022 (cells)
Certification: UL 60691 (fuse component)
Certification: CE, RoHS
Certification: UN 3480, Class 9 (transport)
In the Box
- 24V 230Ah V2-T Elite Series battery (C24230A-A)
- Epoch/Victron communication harness
- Remote digital battery gauge
- External mountable power button
-
Recommended Charging Settings
Program every charge source, Victron equipment included, to these settings:
- Charger type: Lithium (LiFePO4) compatible, CC/CV
- Bulk/absorption voltage: 28.4V
- Absorption time: 15 minutes per battery in the bank (for example, 60 minutes for four batteries)
- Float voltage: 27.0V
- Equalization: Disabled
- Temperature compensation: Disabled (0 mV/°C)
- Maximum continuous charge current: 115A per battery, for all charge sources combined; up to 180A for 5 seconds (the BMS charge over-current protection acts at 180A after a 5-second delay)
- Never charge above 29.0V. Do not use lead-acid equalization, desulfation or repair modes.
- Charge temperature: 0°C to 50°C (32°F to 122°F), with heating support. The cells are not charged below 0°C (32°F); while charging, the 153.6W heater switches on at 5°C (41°F) and off at 10°C (50°F), using incoming charge energy, so the charge source must supply enough current for heating and charging.
- Alternators: use a DC-DC charger or an alternator regulator set up for lithium.
To use the V2-T Elite with Victron systems
- Install and wire the batteries with all chargers and loads off, and set the DIP switches on every battery (see the manual).
- Fit the harness plug with the waterproof bung into the Master battery's blue port.
- For a bank, run an RJ45 cable from the Master's black port to Slave 1's blue port, then from Slave 1's black port to Slave 2's blue port, and so on, up to 16 batteries in parallel. Daisy-chain only; never use branch or tee connections.
- Plug the harness's grey RJ45 plug into the GX device's BMS-CAN port (Cerbo GX or Ekrano GX). On a Cerbo GX Mk2, use VE.Can 1 or VE.Can 2 and set the port speed to 500 kbit/s under Settings › Services › VE.Can.
- Switch on the batteries.
- On the GX device, turn on DVCC, set the controlling BMS to Epoch and set the battery monitor to Epoch.
- To confirm proper reporting, check that the Epoch battery appears in the GX device list. Under the battery's Details, the number of modules online equals the number of batteries installed, and the installed capacity equals the bank capacity (for example, 920Ah for four batteries).
- While charging (not while inverting), the inverter tile shows External control. Under DVCC the system charges to 28.4V, holds absorption for at least about 15 minutes per battery, then floats at 27.0V.
- Manually program the MultiPlus, Quattro and every other charge source to the values above, so charging stays safe if CAN communication is lost.
-
C24230A-A Spec Sheet
C24230A-A User Manual
C24230A-A Technical Data Sheet
V2-T DIP Switch Guide
Safety Data Sheet (LiFePO4)
-
What does “V2-T” mean, and why is the Class-T fuse important?
The V2-T design adds a user-serviceable 300A Eaton Class T fuse to the V2 Elite platform. The C24230A-A uses an Eaton Bussmann JJN-300 rated at 300A with a 20kA interrupting rating at 160V DC, under a protected service cover on the lid. It reduces fault energy at the battery outlet, but it does not replace the main disconnect, downstream conductor protection, branch fusing, or the rest of a code-compliant system design.
If the internal Class-T fuse opens, is the battery ruined?
No. The fuse is replaceable through the protected service-access area. Isolate every source and load, open the main disconnect, verify the system is de-energized, identify and correct the fault, and replace the fuse only with the exact approved model and rating. Restore all covers and seals before returning the battery to service; qualified service is strongly recommended.
Does the 24V V2-T connect directly to a Victron system?
Yes, when installed with Epoch's specified communication harness and configuration. The battery communicates at 500kbit/s over CAN. Connect the designated grey RJ45 lead to the appropriate BMS-Can or configurable VE.Can port on a compatible Cerbo GX or Ekrano GX, set the port as instructed, enable DVCC, and select Epoch as the controlling BMS and battery monitor. Do not assume every generic RJ45 cable has the required battery-side pinout.
Can I connect these batteries in series or parallel?
The C24230A-A user manual supports up to two batteries in series (51.2V nominal, 58.0V at full charge) or up to sixteen in parallel (3,680Ah). Mixed series-parallel banks are not supported. Use C24230A-A batteries of the same age, capacity and state of charge (fully charge each one on its own first), set the DIP switches for the bank, and follow the manual for the selected topology.
How large can a parallel V2-T battery bank become?
Sixteen 5.888kWh batteries provide about 94.21kWh of nominal stored energy and 3,680Ah at 25.6V nominal. Every battery output is a separate source and requires an engineered connection to common busbars, equal-length conductors, appropriate source and branch protection, secure mounting, communication configuration, and professional commissioning.
How does internal self-heating work in freezing conditions?
The battery includes a 153.6W heater controlled by the BMS. The user manual lists low-temperature charge protection at 0°C, heater activation during charging at 5°C, and heater deactivation at 10°C. Available incoming charge energy warms the cells before normal charging proceeds. Charging equipment must still be programmed correctly and provide enough current for heating and charging.
Is the battery completely waterproof?
No. The enclosure is IP67 rated—dust-tight and tested for temporary immersion up to 1 meter for up to 30 minutes when all seals and glands are correctly installed. It is not rated for water jets, pressure washing or continuous submersion. Install the battery where it stays dry in normal use, and make sure all harness connectors are fully seated.
What size inverter can one 24V 230Ah V2-T battery support?
At 25.6V nominal and 115A continuous discharge, the battery provides approximately 2.94kW of nominal DC output before inverter losses. Inverter DC input current ≈ AC load ÷ (25.6V × inverter efficiency): a 2,000W load through a 90%-efficient inverter draws about 87A. If an inverter's continuous DC input can exceed 115A, add batteries in parallel. Final inverter sizing must account for efficiency, surge demand, cable voltage drop, ambient temperature, precharge requirements, downstream protection, and the battery's current limits.
Does the built-in fuse make the installation ABYC compliant?
No single component makes an entire installation ABYC compliant. The integrated Class T fuse reduces fault energy at the battery outlet but does not replace the main fuse, disconnect or branch protection; compliance depends on the complete system—including disconnect location, unfused conductor length, conductor ampacity, overcurrent protection, ignition-protection requirements where applicable, securement, routing, labeling, grounding, and qualified installation.
What can I monitor through Bluetooth?
The Epoch Cloud app (iOS and Android) shows state of charge, cell voltage, temperature, charge and discharge cycles and system health alerts, over Bluetooth 4.0 through the included battery gauge (stay within about 10 m). The gauge also shows state of charge. In a Victron-managed system, the GX device becomes the central view for battery and system data.
What are the dimensions and weight?
The user manual lists the C24230A-A at 20.86 inches long by 8.65 inches wide by 12.06 inches high, with a weight of 98.9 pounds. It uses M8 terminals with a published terminal torque of 12N·m (8.85lb-ft). Confirm compartment clearance, service access, cable bend radius, and mounting hardware before ordering.
-
Epoch Batteries Limited Warranty
11-Year Limited Warranty: 5 Years Free Repair or Replacement
- Years 1–5: free repair or replacement (Epoch chooses which)
- Years 6–11: 40% off MSRP on a replacement battery
Epoch Batteries warrants this product to the original end-user purchaser to be free from defects in materials and workmanship under normal use and service for the warranty period above, when it is installed, operated, charged, stored and maintained as its manual describes. The warranty is not transferable and ends if the product is sold or given to someone else.
How the 40% Discount Works
After the free coverage ends and through Year 11, if the battery has a covered defect Epoch offers a new replacement of the same model (or a current Epoch model of equal or greater capacity and function) at 40% off Epoch's MSRP on the date of the offer. The offer covers one replacement per defective battery, bought directly from Epoch, and you pay the discounted price, any tax and shipping.
When Coverage Starts
Coverage starts on the date of your original purchase. To confirm that date, register the product with Epoch within 90 days of purchase or keep your proof of purchase (an invoice or receipt showing the product, purchase date and seller). If you can provide neither, coverage starts on the manufacturing date recorded for the product's serial number. A repaired or replacement product is covered for the rest of the original warranty period.
What Is Not Covered
The warranty covers defects in materials and workmanship only. It does not cover damage or failure caused by installation, wiring or system design that doesn't follow the manual (including undersized or damaged cables, poor crimps, loose or corroded connections and incorrect fusing); reverse polarity, short circuits or faults in the connected electrical system; series or parallel connections beyond the manual's limits, or mixing batteries of different models, capacities, ages or states of charge; a product not secured as the manual requires; charging outside the manual's voltage, current or temperature limits; discharge above the rated current, or engine starting with a battery not listed as a starting or dual-purpose battery; over-discharge, storage fully discharged, or storage for more than 3 months without recharging; accidents, impact, fire, flood, power surges, submersion or exposure beyond the product's IP rating; opening, modification or repair by anyone other than Epoch or an Epoch-authorized provider; removed or altered serial numbers; normal capacity loss and wear consistent with age and use; or cosmetic damage that doesn't affect performance. Using chargers and other equipment from other brands does not affect coverage by itself.
Obtaining Warranty Service
Start a claim through the Epoch Warranty Portal before the warranty period ends, with the model, serial number, proof of purchase or registration, a description of the problem and any photos, videos or app screenshots. If the claim qualifies, Epoch issues an RMA number with packing and shipping instructions; do not ship a product without an RMA. Epoch inspects and tests the product, typically within 3–10 business days after it arrives, and then repairs or replaces it, or makes the discount offer where applicable.
Shipping
You pay to ship the battery to Epoch; Epoch pays to ship an approved warranty repair or free replacement back to you. For discount replacements you pay shipping on the replacement battery. Packaging must follow the RMA instructions (lithium batteries are regulated hazardous materials in transport).
Visit Epoch's Warranty Page to review the complete warranty terms (effective October 17, 2026).
-
Shipping is typically through freight carriers and the actual shipping time is contingent on your location and the specific warehouse dispatching your order. Please allow for a 1-3 business day processing period before shipment, and an estimated delivery time of up to 7 business days. Your confirmation email will include delivery details and we will send you a tracking number as soon as one is available. If you ordered several separate items, you may receive multiple tracking numbers. Once the item has been shipped, the freight service will contact you to coordinate the date and time of delivery. If you require any special accommodations during delivery please let us know as soon as possible and let the delivery company know when arranging the appointment.
Typically, orders will be dropped off either curbside or outside your front door or garage. It is your responsibility to bring the order inside or to its final destination and to remove any existing items.
Depending on the item, parts may be shipped in multiple boxes, and assembly may be required. When your order is delivered, please check that you have all pieces of the item and that nothing is damaged. If your order is damaged during transit and external damage is visible, note the damage immediately, write it on the delivery documents, take photos and/or videos, and refuse shipment. If there is no visible external damage, accept the package but note “subject to concealed damage” on the delivery documents. Any damage upon delivery needs to be reported within 24 hours of delivery or you may not be eligible for a refund. For additional information on submitting claims, as well as incorrect item exchanges, and replacements, please see our Refund Policy.
For more information about shipping, please visit our complete Shipping Policy.
-
Why Shop With Eco Emperor?
At Eco Emperor, our mission is to empower you to lead a sustainable and fun lifestyle with ease and confidence. Whether you're upgrading your outdoor experience or enhancing your eco-conscious journey, here’s why choosing us is a decision you can feel great about:
Expert and Customized Care
Our knowledgeable and friendly team is here to support you every step of the way. We pride ourselves on providing personalized service and swift responses to ensure a smooth and satisfying experience. Our dedicated team is available via phone, email, and live chat to provide you with prompt and helpful support.
Authorized Retailer of High-Quality, Trusted Products from Leading Brands
We partner with the best brands in the industry to bring you reliable, high-quality products. As authorized retailers, we guarantee authenticity and offer full manufacturer warranties on every item. You can trust that our products are built to last and perform efficiently.
Free & Fast Shipping
We know you’re eager to begin your new products or start your next outdoor adventure. That’s why we prioritize quick, reliable, and free shipping to get your orders to you on time and in perfect condition.
Competitive Pricing
We believe that sustainable living should be accessible to everyone. We offer competitive pricing on all our products, so you can enjoy high-quality eco-friendly solutions and outdoor products without breaking the bank.
Choose Eco Emperor for all your outdoor and eco-friendly product needs, and become part of a movement that’s embracing a more sustainable and adventurous lifestyle.
Thank you for supporting a greener, cleaner future, while enhancing your outdoor experiences and powering your adventures.💚